• 0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470
  • 0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470
0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470

0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470

Detail produk:

Tempat asal: Dongguan,Guangdong,China
Nama merek: UCHI
Sertifikasi: ROHS,SGS,CTI etc.
Nomor model: CZT470

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1000PCS
Harga: Negotiable
Kemasan rincian: Bulk
Waktu pengiriman: 7-10 workdays
Syarat-syarat pembayaran: T/T, Western Union, MoneyGram,Paypal
Menyediakan kemampuan: 50000pcs per week
Harga terbaik Kontak

Informasi Detail

Product Name: Weighing Cell Outer dimension: 45*9*6
Model number: CZT470 Type: Load cell
Rated capacities: 0.3kg,0.5kfg,1kgf Rated output: 1 ±0.15 mV/V
Output terminal resistance: 1000±5 Ω Input terminal resistance: 1055±15 Ω
Safe overload: 200 %F.S Delay: 0.015(%F.S.)
Degree of linearity: 0.015(%F.S.) Protection Level: C3
Material: Metal ODM/OEM: Available
Origin: Dongguan,Guangdong,China Factory location: Dongguan
Cahaya Tinggi:

sensor suhu thermocouple

,

Probe NTC sensor suhu

Deskripsi Produk

 

0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470

 

Load Cell Terminology

 

Each country has its own standard for the performance and quality of load cells.In Japan, there is no standard stipulated uniquely for load cells, although JIS(Load Cell - Test Method JIS B7602) and JMIF (Japan Measuring Instruments Federation) prescribe methods for performance tests.
Meanwhile, the OIML (International Organization of Legal Metrology) sets the international recommendation titled “Metrological Regulation for Load Cells,” with which each member country tries to make their local regulation consistent.The terms described below are commonly used by the OIML and its member countries.


Rated Capacity (RC)
The maximum load that a load cell can measure while meeting its specifications.


Rated Output (RO)
The difference when there is no load and when there is a load of rated capacity. It is generally expressed in output per excitation voltage (mV/V). Alternatively called “Span.”


Safe load limit
The maximum load that can be applied beyond the rated capacity without causing any permanent damage. Expressed as a percentage of rated capacity. 


Compensated temperature range
The temperature range within which the rated output and the zero balance are compensated to meet the specifications.


Temperature effect on zero balance
Drifting of the zero balance caused by changes in the ambient temperature.Expressed as a percentage of rated output.


Temperature effect on rated output
Drifting of the rated output caused by changes in the ambient temperature.

 

Nonlinearity
The maximum deviation in output from the linear calibration curve linking the zero balance and the rated output, which is measured only when the load increases. Expressed as a percentage of rated output.


Hysteresis error
The maximum difference in output between when the load increases and when the load decreases.


Combined error
The maximum deviation of output from the linear calibration curve linking the zero balance and the rated output, including when the load increases and decreases.


Recommended/maximum excitation voltage
The voltage applied to the input terminals of load cell.


Zero balance
The electrical output when the rated excitation voltage is applied without any load on the cell. Generally expressed as a percentage of rated output.


Input terminal resistance
Measured while the output terminals are open, with no load on the cell.


Output terminal resistance
Measured while the input terminals are open, with no load on the cell.


Insulation resistance
The direct current resistance between the load cell unit and its circuit.

 

Recommended excitation voltage 5-15V, maximum excitation voltage 15V.
Red (red): E+ black (black): E- white (white): V- blue or green (or green blue): V+
Widely used in high precision, small measuring range weighing occasions, with good lateral, torsional, anti offset properties for miniature automatic detection equipment, compact test equipment, trace weighing equipment, push and pull device, tension and pressure testing, according to the user's requirements and dimensions of custom sensors.
Optional fit weight transmitter, weighing display meter, weighing control table, weighing alarm instrument (additional charge),

 

 

Where are load cells used?

0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470 0

 

 

Features

 

Ultra compact design

Adjusted for all kinds of loads.

Moisture proof

Wide model selection

 
 
Specifications
 
 
Technical  Unit Data
Range kg 0.3/0.51
Output sensitivity mV/V 1.0±0.15
Synthetic error %F.S 0.03%
Zero drift (30min)%F.S 0.05/0.03
Zero temperature drift %F.S/10Deg C 0.05/0.03
Zero output mV/V ±0.1
Input resistance Ω 1055±15
Output resistance Ω 1000±5
Overload capcity %F.S

200

 

 

 

Product Photos

 

0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470 1

Ingin Tahu lebih detail tentang produk ini
0.3kfg 0.5kfg 1kfg Pocket Weight Scale Sensor Palm Jewelry Weight Cell CZT470 bisakah Anda mengirimkan saya lebih banyak detail seperti jenis, ukuran, jumlah, bahan, dll.
Terima kasih!
Menunggu jawaban Anda.