Detail produk:

Tempat asal: Dongguan,China
Nama merek: UCHI
Sertifikasi: ROHS,UL,cURus,HF,PB FREE
Nomor model: 0603

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1 Reel
Harga: Negotiable
Kemasan rincian: Reel
Waktu pengiriman: 7 Workday
Syarat-syarat pembayaran: T/T,Western Union,Paypal
Menyediakan kemampuan: 50000000PCS Monthly
Harga terbaik Kontak

Informasi Detail

Cahaya Tinggi:

slow blow glass fuse

,

mini glass fuses

Deskripsi Produk

Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission
 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission​ Description
 
06 110 Series are the fuses set the industry standard for performance, reliability and
quality. The solder‐free design provides excellent on‐off and temperature cycling
characteristics during use and also makes our SMD fuses more heat and shock
tolerant than typical subminiature fuses.

 

Electrical Characteristics
Rated Current1.0In2.0In2.5In
1A~8A4 hour minimum1~60 sec5 sec maximum

 

 
 

0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Features

 

High inrush current withstanding capability
Compatible with reflow and wave solder
Ceramic and glass construction
Excellent environmental integrity
One time positive disconnect
Lead Free and Halogen free material

 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Specifications
 
 

Specification
Part No.

Rated

Voltage

Rated

Current

(A)

Breaking

Capacity (A)

1

Typical Cold.

Resistance

(mOhms) 2

 

Typical Voltage

Drop (mV)

Typical Pre-
Arcing I2t
A2Sec)3

Alpha

Mark

Part No.

DC

 

Rated

Current

(A)

Breaking

Capacity (A)

1

Typical Cold.

Resistance

2

(mOhms)

Typical Voltage

Drop (mV)

Typical Pre-

2

Arcing I t

2 3

(A Sec)

Alpha

Mark

06 100.132V150A257.52950.018B
06 100.1.532V1.550A137.52200.065H
06 100.232V250A721600.115K
06 100.2.532V2.550A521450.14L
06 100.332V350A351300.21O
06 100.3.532V3.550A23.81300.55R
06 100.432V450A211200.52S
06 100.532V550A141101.70T
06 100.632V650A81102.30V
06 100.732V750A5.6903.0X
06 100.832V850A3.5805.2Z

 

 
 

* DC Interrupting Rating (Measured at rated voltage, time constant of less than 50 microseconds, battery source)
* DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25degrees
* Typical Pre-arching I2t are measured at 10In Current

 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Dimension
 
Drawing not to scale (Unit: mm/inch)
 
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission 0
 
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission 1

Ingin Tahu lebih detail tentang produk ini
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission bisakah Anda mengirimkan saya lebih banyak detail seperti jenis, ukuran, jumlah, bahan, dll.
Terima kasih!
Menunggu jawaban Anda.